    Your current location: home page > Article technology >Analysis of common problems and solutions of capsule filling machine

    Analysis of common problems and solutions of capsule filling machine

    Release time: March 23, 2020 number of hits: 1181
       Capsule filling machine It integrates machine, electricity and gas, adopts microcomputer programmable controller, touch panel operation, frequency conversion and speed regulation, and is equipped with electronic automatic counting device. It can automatically complete the actions of capsule positioning, separation, filling and locking, which can reduce labor intensity, improve production efficiency and meet the requirements of pharmaceutical hygiene. The machine is sensitive in action, accurate in filling dose and convenient in operation. It is suitable for filling various domestic or imported capsules. It is an economical and practical equipment for filling capsule drugs in pharmaceutical industry.
     
    The following is a brief introduction Capsule filling machine The common faults and solutions are as follows:
     
    1. There are too many inverted heads of capsule shell (more than 3%), and the vibrator is not adjusted properly. The qualified capsule shell is selected because of the proper voltage adjustment or the capsule shell size is not up to standard.
     
    2. The guide plate in the mold is worn, which affects the low encapsulation rate of the capsule. Replace the new mold or the positioning on both sides is loose. Tighten the positioning nail. If the capsule is deformed or wet, replace the capsule shell.
     
    3. The capsule shell is arranged in the working table board, and the mouth is higher or lower. Adjust the height of the dislocation plate and the guide rail.
     
    4. The mold cannot be reset in the track, and the compression spring at the rear end of the guide rail is stuck or the capsule variant is stuck. Re install the spring or ejector pin, and push down the stuck capsule with the push rod.
     
    5. The vibration is not ideal, adjust the voltage.
     
    6. Screw of H plate is loose, and tighten the screw.
     
    7. If the capsule shell is stuck on the platen and cannot fall down, replace the capsule shell or adjust the position of the dislocation plate and platen hole.
     
    Through the above content, I hope to help you operate the capsule filling machine.